SAMSUNG F-AC090HCAFK01 Ducted System. Single Phase / with Backlit Wired Controller MWR-WE10

$2,740.00

SAMSUNG F-AC090HCAFK01 Ducted System. Single Phase. Indoor AC090HBHFKH/SA – Outdoor AC090HCAFKH/SA / Backlit Wired Controller MWR-WE10 / 9.0kW Cool – 10.0kW Heat

Description

SAMSUNG DUCTED SYSTEM

 

Type Duct S
Model Name Indoor Unit AC090HBHFKH/SA
Outdoor Unit AC090HCAFKH/SA
System Capacity Cooling (Min/Std/Max)1 kW 2.60/9.00/11.50
Heating (Min/Std/Max)2 kW 2.80/10.00/15.50
Power Power Input (Nominal) Cooling (Min/Std/Max) kW 0.70/2.60/4.50
Heating (Min/Std/Max) kW 0.65/2.50/5.50
Current Input (Nominal) Cooling (Min/Std/Max) A 4.00/12.00/19.50
Heating (Min/Std/Max) A 3.40/11.50/21.80
MCA A 26.70 (MCA)
MFA A 30.00
Energy Efficiency EER (Nominal Cooling) 3.46
COP (Nominal Cooling) 4.00
Energy Grade AEER 3.38
ACOP 3.97
Pipe Connections Liquid Pipe ɸ, mm(inch) 9.52 (3/8)
Gas Pipe ɸ, mm(inch) 15.88 (5/8)
Installation Limitation Max. Length m 50
Max. Height m 30
Field Wiring Power Source Wire ɸ, mm 4.00
Transmission Cable ɸ, mm 0.75 ~ 1.25
Refrigerant Type R410A
Factory Charging Kg 2.60 (charged for 30m)
Indoor Unit Power Supply ɸ, #, V, Hz 1,2,220-240,50/60
Fan Air Flow Rate Max/H/M/L ℓ/s 633.33/533.33/450.00/366.67
External Static Pressure Min/Std/Max Pa 30.00/ 50.00/ 150.00
Drain Drain Pipe VP25 (OD 32, ID 25)
Sound Sound Pressure3 High/ Mid/ Low dB(A) 38.00
External Dimsion Net Weight kg 31.50
Shipping Weight kg 36.50
Net Dimensions (WxHxD) mm 1,200 x 250 x 700
Supply Air Opening (WxH) mm 1168 x 220
Return Air Opening (WxH) mm 1168 x 220
Shipping Dimension (WxHxD) mm 1,450 x 320 x 780
Outdoor Unit Power Supply ɸ, #, V, Hz 1,2,220-240,50/60
Compressor Type Twin BLDC Rotary
Fan Air Flow Rate Cooling ℓ/s 1,050.00
Sound Sound Pressure3 Cooling/ Heating dB(A) 49.0/52.0
External Dimsion Net Weight kg 70.00
Shipping Weight kg 74.00
Net Dimensions (WxHxD) mm 940 x 998 x 330
Shipping Dimension (WxHxD) mm 995 x 1,096 x 426
Operating Temp. Range Cooling -15 ~ 50
Heating -20 ~ 24
1) Nominal cooling capacities are based on;
Indoor temperature: 27℃ DB, 19℃ WB
Outdoor temperature: 35℃ DB, 24℃ WB, Equivalent refrigerant piping: 5m, Level difference: 0m
2) Nominal heating capacities are based on;
Indoor temperature: 20˚DB, 15˚WB
Outdoor temperature: 7˚DB, 6˚WB, Equivalent refrigerant piping: 5m, Level difference: 0m
3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. Specification may be subject to change without prior notice due to product development.

Reviews

There are no reviews yet.

Be the first to review “SAMSUNG F-AC090HCAFK01 Ducted System. Single Phase / with Backlit Wired Controller MWR-WE10”

Your email address will not be published. Required fields are marked *