SAMSUNG F-AC140HCAFK01 Ducted System. Single Phase. Indoor AC140HBHFKH/SA – Outdoor AC140HCAFKH/SA / Backlit Wired Controller MWR-WE10 / 14.0kW Cool – 16.0kW Heat

Description

SAMSUNG DUCTED SYSTEM

 

Type Duct S
Model Name Indoor Unit AC140HBHFKH/SA
Outdoor Unit AC140HCAFKH/SA
System Capacity Cooling (Min/Std/Max)1 kW 3.50/14.00/15.40
Heating (Min/Std/Max)2 kW 3.70/16.00/21.00
Power Power Input (Nominal) Cooling (Min/Std/Max) kW 0.95/4.12/5.40
Heating (Min/Std/Max) kW 0.85/3.98/7.50
Current Input (Nominal) Cooling (Min/Std/Max) A 5.00/18.80/24.00
Heating (Min/Std/Max) A 4.50/18.40/31.60
MCA A 34.70 (MCA)
MFA A 40.00
Energy Efficiency EER (Nominal Cooling) 3.40
COP (Nominal Cooling) 4.02
Energy Grade AEER 3.31
ACOP 3.94
Pipe Connections Liquid Pipe ɸ, mm(inch) 9.52 (3/8)
Gas Pipe ɸ, mm(inch) 15.88 (5/8)
Installation Limitation Max. Length m 75
Max. Height m 30
Field Wiring Power Source Wire ɸ, mm 4.00
Transmission Cable ɸ, mm 0.75 ~ 1.25
Refrigerant Type R410A
Factory Charging Kg 2.90 (charged for 30m)
Indoor Unit Power Supply ɸ, #, V, Hz 1,2,220-240,50/60
Fan Air Flow Rate Max/H/M/L ℓ/s 1000.00/700.00/566.67/416.67
External Static Pressure Min/Std/Max Pa 30.00/ 60.00/ 200.00
Drain Drain Pipe VP25 (OD 32, ID 25)
Sound Sound Pressure3 High/ Mid/ Low dB(A) 40.00
External Dimsion Net Weight kg 45.50
Shipping Weight kg 51.50
Net Dimensions (WxHxD) mm 1,300 x 300 x 700
Supply Air Opening (WxH) mm 1268 x 270
Return Air Opening (WxH) mm 1268 x 270
Shipping Dimension (WxHxD) mm 1,550 x 370 x 780
Outdoor Unit Power Supply ɸ, #, V, Hz 1,2,220-240,50/60
Compressor Type Twin BLDC Rotary
Fan Air Flow Rate Cooling ℓ/s 1,916.67
Sound Sound Pressure3 Cooling/ Heating dB(A) 51.0/52.0
External Dimsion Net Weight kg 98.00
Shipping Weight kg 108.00
Net Dimensions (WxHxD) mm 940 x 1,420 x 330
Shipping Dimension (WxHxD) mm 995 x 1,597 x 426
Operating Temp. Range Cooling -15 ~ 50
Heating -20 ~ 24
1) Nominal cooling capacities are based on;
Indoor temperature: 27℃ DB, 19℃ WB
Outdoor temperature: 35℃ DB, 24℃ WB, Equivalent refrigerant piping: 5m, Level difference: 0m
2) Nominal heating capacities are based on;
Indoor temperature: 20˚DB, 15˚WB
Outdoor temperature: 7˚DB, 6˚WB, Equivalent refrigerant piping: 5m, Level difference: 0m
3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. Specification may be subject to change without prior notice due to product development.